TYBQ-12-4 Portable High-Energy Igniter

TYBQ-12-4 Portable High-Energy Igniter

Built for field servicing and burner start-up, the portable high energy igniter stores 12J per ignition pulse and delivers roughly 2500V, while its DC24V 2.4Ah lithium battery keeps this high energy igniter ready for gas turbine, industrial burner, and backup ignition work where mains power is limited.

TYBQ-12-4 Portable High-Energy Igniter,MY SHOP,TYBQ-12-4 Portable High-Energy Igniter
TYBQ-12-4 Portable High-Energy Igniter with 12J energy storage and approximately 2500V output.
12J Per Pulse, 2500V Output, Battery Powered
12J Per Pulse, 2500V Output, Battery Powered

12J Per Pulse, 2500V Output, Battery Powered

The TYBQ-12-4 is a portable high energy igniter built for field servicing and burner start-up. Each ignition pulse stores 12J and delivers approximately 2500V, at a spark frequency of about four cycles per second, so the unit can start a burner or gas turbine where mains power is limited or intermittent.

The ignition circuit uses high-frequency voltage boosting with solid-state discharge. That combination is what the manufacturer credits for the circuit efficiency and the extended service life, and it is why the unit is described as suited to backup ignition in remote power installations.

Power comes from a DC24V 2.4Ah lithium battery. The housing is modular and compact with a simplified interface, so technical staff can put it into service quickly, and the battery life is stated to support extended field operations.

Key Features

How this part is built and what each detail changes for the buyer.

12J Energy Storage

Each ignition pulse stores 12J of energy, which is what allows reliable ignition in demanding combustion conditions.

Approximately 2500V Output

The output voltage is approximately 2500V per pulse.

About 4 Cycles Per Second

Spark frequency is stated at roughly four cycles per second, giving repeatable ignition attempts.

DC24V 2.4Ah Lithium Battery

A lithium battery pack powers the unit for off-grid and backup ignition work.

Solid-State Discharge Circuit

High-frequency voltage boosting with solid-state discharge is used for circuit efficiency and extended circuit lifespan.

Q/TYQ 01-2021 Compliance

The unit is stated to comply with standard Q/TYQ 01-2021.

Specifications

The published figures for this product, as stated on the supplier's product page.

12J Per Pulse, 2500V Output, Battery Powered - published details
Item Detail
Model TYBQ-12-4
Battery setup DC24V 2.4Ah, lithium battery
Energy storage 12J
Output voltage Approximately 2500V
Spark frequency Approximately 4 cycles per second
Standard compliance Q/TYQ 01-2021
Technology High-frequency voltage boosting with solid-state discharge
Configuration Portable, battery powered, modular housing

The product page does not state weight, dimensions, operating temperature, IP rating, price, MOQ or warranty for this model. Those figures are confirmed with the quote rather than assumed from the listing.

Ignition Duties This Unit Covers

The applications and buyer situations this product is supplied for.

Combustion furnace startup
Gas turbine ignition
Industrial burner maintenance
Ignition circuit testing
Field servicing
Backup ignition in remote installations

These are the applications listed on the product page for the TYBQ-12-4 igniter.

Request a Quote for the TYBQ-12-4

Send the burner or turbine you need to ignite, the ignition duty and the quantity required, and the supplier will confirm the configuration and the published specification for your application.

Related Reading

Three notes to help clarify product requirements before contacting the supplier.

Spark Energy, Voltage, and Frequency in Industrial Igniters-TENGYAN

A spec sheet for a high energy igniter usually lists three numbers side by side — stored energy, output voltage, and spark frequency — and each one answers a different question.-TENGYAN

Read article

12J High Energy Igniters Differ from Standard Industrial Spark Igniters-TENGYAN

Understanding the gap between a 12-joule ignition pulse and a millijoule-level spark explains why some burners light on the first attempt while others keep refusing to start.-TENGYAN

Read article

Why Solid-State Discharge Makes Industrial Igniters More Reliable-TENGYAN

Solid-state discharge changes how an industrial igniter switches stored energy, so reliability depends less on wearing contacts and more on circuit design.-TENGYAN

Read article

Frequently Asked Questions

what are the main specifications of the tybq-12-4?

the tybq-12-4 stores 12j per ignition pulse, produces approximately 2500v, and sparks at about four cycles per second. it runs on a dc24v 2.4ah lithium battery and complies with standard q/tyq 01-2021.

which applications is this igniter designed for?

typical uses listed for the product include combustion furnace startup, gas turbine ignition, industrial burner maintenance, ignition circuit testing and troubleshooting, field servicing, and backup ignition in remote power installations.

how does the solid-state discharge design improve reliability?

the igniter uses high-frequency voltage boosting together with solid-state discharge, which the product page associates with improved circuit efficiency and a longer circuit service life.

is the unit suitable for off-grid or mobile ignition work?

yes. it is a portable, battery-powered design with a compact modular layout, which suits off-grid and backup ignition where power may be limited or intermittent.

what should i confirm before placing an order?

confirm the model tybq-12-4, the dc24v 2.4ah lithium battery configuration, and the 12j, approximately 2500v and approximately 4 hz figures against your ignition system requirements.

how do i request a quote or technical support?

send your application details, required quantity, and specification questions through the contact page, and the supplier will reply with pricing and technical guidance.