Plasma Igniter TYDQ-2 Input parameter AC220V 10A

Plasma Igniter TYDQ-2
Input: AC220V 10A
Output: 10KV 20KHz
Standard: Q/TYQ 01-2021
Download
View all downloads
  • Plasma Igniter TYDQ-2,MY SHOP,Plasma Igniter TYDQ-2

Description

Product Overview

This plasma igniter is the simpler of our two plasma units: a single cabinet that takes an ordinary AC220V supply and turns it into the high-voltage, high-frequency discharge the burner needs at light-off. It carries the ignition duty on its own. There is no battery pack to keep charged and no flame-detection head sharing the housing, which suits a plant that already has its monitoring and control in place and simply wants a dependable arc at the burner. The enclosure is a rectangular stainless steel cabinet with two carry handles on top, so one technician can lift it into a plant room or onto a bench without rigging. The front panel carries the red and green control buttons, a fan vent keeps air moving through the cabinet during a start sequence, and the power cable is already attached — commissioning starts with a supply and an earth rather than a wiring exercise. Most of these units go in where a contact-type igniter has been losing reliability. There are no breaker points in the discharge path to erode, and that erosion is the usual reason a conventional igniter starts to miss as it ages. The same cabinet is the plasma igniter device for waste incineration plant duty and also handles boiler light-off, kiln and furnace burners. Because we build the discharge circuit and the panel ourselves as a high voltage plasma igniter manufacturer, a change at the ignition end does not mean a new supplier.

Ignition Output and Arc Behaviour

  • 10 kV at the ignition point. The output voltage is high enough to break down the gap at the torch or nozzle and strike an arc into the fuel and air mixture, instead of hoping a small spark lands at the one moment the mixture is right.
  • 20 kHz repetition through the light-off window. The discharge repeats continuously while the unit is running, so the burner sees a dense train of arcs rather than a single tick. On a slow-lighting fuel that is what removes the second and third start attempt.
  • All-solid-state high-frequency boost. The voltage is stepped up electronically, with no interrupter contacts in the discharge path to pit or wear, so the output does not fade as the cabinet warms through a start sequence.
  • Steady where the supply is not. Few plants have a perfect 220 V at the far end of a long run; the solid-state circuit copes with the small dips and rises that a mechanical igniter turns into a missed spark.
  • Drives a separate front end. The arc itself forms at the plasma torch, gun or nozzle fitted to the burner port, and that front end sets the arc length and the air or fan arrangement. The two have to be matched, and we check that before the order goes ahead.
  • Start and stop from the panel. The red and green buttons let a commissioning technician run the unit while watching the flame at the burner, with no laptop or remote signal needed.
  • Fan-cooled cabinet. Air moves through the housing the whole time the unit is energised, which matters most during a run of start attempts when the electronics work hardest.

Specifications

ModelTYDQ-2
Device typePlasma ignition power and control unit
Input supplyAC220V
Input current10 A
Output voltage10 kV
Output frequency20 kHz
Governing standardQ/TYQ 01-2021
EnclosureRectangular stainless steel housing
HandlingTwo carry handles on top
Control panelRed and green push buttons
CoolingFan-vented cabinet
Power connectionAttached power cable

Where The Unit Is Installed

Incineration is the duty most of these units are specified for. A plasma igniter device for waste incineration plant service is judged on one thing: whether the fuel catches on the first or second attempt, because every retry stretches the start-up window and pushes steam production back. Refuse-derived fuel arrives wet and variable, so the igniter has to keep an arc going through the whole light-off period rather than deliver one spark and stop. Boiler light-off on coal, oil or gas follows the same logic. A plasma ignition system that repeats its discharge at high frequency establishes flame quickly enough for the burner to be brought up in a controlled ramp, and it does not leave the operator guessing whether the arc actually landed in the mixture. Kiln burners, process furnaces and biomass units use the same cabinet wherever the front end is a plasma torch or nozzle rather than a conventional spark plug. Retrofit work is the other common case: a plant pulls out a contact-type igniter that has been eating maintenance hours and puts this unit in its place, keeping the existing burner port and front end where they still check out. Boiler, burner and kiln OEMs take the same cabinet into new packages, where it is specified as the ignition source and the flame monitoring is handled by their own burner management system. Treat it as a start-up device. The arc establishes the flame, and from there the burner's fuel control and flame detection take over the run.

Installation and Commissioning

  1. Check the supply first. Measure AC220V at the point where the cabinet will sit and confirm the circuit can carry the 10 A draw before anything is unpacked.
  2. Set the cabinet in place. Leave the fan vent clear on all working sides and keep the carry handles reachable so the unit can be lifted out later. Route the power cable away from hot pipework and from the high-voltage lead.
  3. Bond the enclosure to the plant earth before the unit is energised, and confirm the earth point with the site electrical team.
  4. Fit the front end. Mount the plasma torch, gun or nozzle in the burner port, then run the high-voltage lead back to the cabinet as short and as direct as the layout allows, kept apart from signal and instrumentation cables.
  5. Run a dry test with fuel off. Start the unit from the panel, watch for a steady arc at the front end, then stop it and inspect the tip for tracking or soot before going further.
  6. Commission with the burner. Bring the burner through its normal start sequence and confirm the flame signal holds inside the trial-for-ignition time the burner management system allows.
  7. Record what you set. Note the front-end gap, the lead route and the panel position so the next maintenance shift starts from the same baseline instead of re-learning it.

Service Checks Between Shutdowns

  • Keep the fan vent clear. Dust and fly ash are the usual reason a plasma igniter device for waste incineration plant service runs hot. Vacuum the vent at each planned shutdown rather than blowing dust back into the housing.
  • Wipe the cabinet, not the panel. A damp cloth is enough for the stainless housing, and solvents should stay away from the button legends and the rating label.
  • Look at the input terminals and the cable gland. Vibration loosens terminals over a long run; a quick check with the supply isolated catches a loose connection before it becomes intermittent starts.
  • Inspect the ignition end every shutdown. Carbon build-up and an electrode gap that has opened up are the two things that quietly add start attempts. Clean the tip and reset the gap — around 3 to 5 mm is the usual setting — before the next light-off.
  • Check the high-voltage lead. Cracked insulation or tracking marks along the lead cause missed arcs that look like a faulty cabinet, and the lead is much cheaper to replace than the unit.
  • Keep a spare on the shelf. A second unit or a spare front end lets the maintenance team swap, test and keep the start sequence on schedule while the suspect part is examined.
  • Log the start attempts. A rising count of retries is the earliest sign of a front-end or supply problem, and it is far cheaper to fix before a failed light-off than after one.

Choosing Between The Two Plasma Units

ConfigurationThis unitTYDQ-1
Input supplyAC220V, 10 AAC220V
Output10 kV / 20 kHz10 kV / 20 kHz at 1000 W plasma output
Flame detectionIgnition onlyUV detector with switching output
Backup powerMains supply only48 V / 20 Ah lithium battery, 5 A charging
Governing standardQ/TYQ 01-2021Q/TYQ 01-2021
Typical dutyIncineration, boiler and kiln light-offPetrochemical and process furnace duty with flame verification
Panel footprintIgnition cabinet onlyIgnition, detection and battery in one system

Ordering and Delivery

  1. Send the burner details first — the fuel, the burner type, the model or a photo of the igniter coming out, and the port the front end fits into. That is enough for us to confirm the model.
  2. Confirm the supply and the position. Tell us the voltage and current available at the panel and the space around the cabinet, so nothing has to be re-planned on delivery.
  3. Confirm the front end and the lead. If the port or the lead route is non-standard, say so at this stage; as a high voltage plasma igniter manufacturer we would rather check the torch or nozzle geometry before the order than after.
  4. Agree quantity and delivery date. Lead time is confirmed for the batch at the time of order with your sales contact, once the configuration is fixed.
  5. Settle packing and shipping. Export packing, mode of transport, port and shipping terms are confirmed per order with your sales contact — tell us if the site needs the cabinet crated for a long inland leg.
  6. Confirm payment terms and paperwork. Payment, invoice details and any documentation you need for customs or a project file are agreed with your sales contact before dispatch.
  7. Ask about spares. A second unit or a spare front end can be added to the same order so the plant is never waiting on a single item.

Technical Support & Model Matching

Not every buyer arrives knowing which item in the range fits. Tell us what the part has to do, the space it goes into and the supply you have, and our engineers check it against the specifications we publish and tell you which model matches — and when a standard item will not do. The same team designs, builds and tests the products in our own plant in Shaanxi: 28 people, 16 patents, national high-tech enterprise status, in business since 2018. They answer questions before you order, stay reachable afterwards for fitting questions and fault-finding, and take custom or non-standard requests directly.

FAQ

What supply does the unit need at the panel?

It runs on AC220V and takes up to 10 A, so the circuit feeding it has to be rated for that. Before ordering, check the breaker and the cable at the point where the cabinet will sit, and tell us if the available supply is different — a 220 V circuit that already carries other loads is worth reviewing with us before the unit arrives.

Do I need a torch or nozzle as well as the power unit?

Yes. This cabinet is the power and control half of a plasma ignition system. The arc forms at the plasma torch, gun or nozzle fitted to the burner port, and the high-voltage lead carries the pulse between the two. Send us the port thread, the insertion depth you have available and the length of the run, and we will confirm which front end and which lead go with the unit.

Will it light wet refuse-derived fuel in an incineration plant?

That is the duty it is most often bought for. It sustains a high-frequency discharge through the whole light-off window rather than firing a single spark, which is what wet, low-grade fuel needs before it will catch. Tell us the fuel and the burner type and we will confirm the front end to go with it.

What should I check first if the arc stops?

Work outwards from the supply. Confirm 220 V is present at the cabinet, then inspect the ignition end for carbon build-up and for an electrode gap that has opened up — around 3 to 5 mm is the usual setting. A cracked or tracking high-voltage lead is the next thing to look at. If the front end is clean and the supply is good, the discharge components inside the cabinet are the parts to go through with us.

What does the Q/TYQ 01-2021 standard cover?

It is the standard this unit is designed, built and tested against, covering the construction of the ignition unit and its electrical performance rather than an installation approval. If you need the documentation for a project file, ask your sales contact for the current pack when you place the enquiry.

Can I order the whole ignition chain from one supplier?

Yes. As a high voltage plasma igniter manufacturer we build the power unit, the plasma torch and nozzle front ends, the ignition cable and the electrodes, so a start-up package can be matched before it ships instead of being assembled from three suppliers on site. Send the burner details once and we will put the set together around them.