Ultraviolet UV Tube Day-blind type

Ultraviolet UV Tube
- Components used are imported. Wavelength range comes in at 185 to 260nm and is not affected by sunlight
- Works between -20°C and 60°C
- Expected to last for a total of 25,000 hours
Download
View all downloads
  • Ultraviolet UV Tube,MY SHOP,Ultraviolet UV Tube

Description

Product Overview

The working part of a flame detector is the tube behind its window. Ultraviolet light from the flame strikes the tube, and the tube produces the small current the detector's electronics turn into a flame-on signal. Everything else at the front end — the housing, the sighting tube, the window, the cooling and the cable — belongs to the detector. This part supplies the eye. It goes back into the detector already on your burner and puts the installation back to the state it was in when the firing was commissioned: no new amplifier, no new mounting, no change to the burner management logic. That matters on a plant where the detector was chosen years ago and the drawings have long since gone quiet. Most of what leaves our workshop goes to boiler houses and burner fronts as a UV tube for boiler flame detection, and the same tube serves furnace, kiln and incinerator detectors working in the same window. Buyers are usually maintenance engineers holding a failed head, or a spare-parts desk restocking ahead of a shutdown. Either way the question is the same one — which tube belongs in which detector.

Key Features

  • Day-blind sensing — response is confined to the band below 260 nm, so daylight falling on the sighting port produces no flame signal at all. - A tube change, not a detector project — it seats into the detector already fitted to the burner; the amplifier, wiring and mounting stay exactly as they are. - Imported tube components, checked here — the sensing element is imported, and assembly and the final check before packing happen in our own workshop. - Referenced to your detector — supplied against the model on your nameplate rather than as a near-size lamp, with the reference confirmed before dispatch.

Matching the Tube to the Detector

  1. Read the detector nameplate first. The make, model and part number on the detector decide which tube seats and which spectral response the amplifier expects. Get those before anything is unscrewed.
  2. Read the old tube before it goes in the bin. The reference is usually printed on the tube or on the carton it arrived in. If it has worn away, photograph the tube from both ends against a plain background.
  3. Note the duty and the surroundings. Boiler front, furnace wall or kiln hood, plus how warm the detector head runs in summer, all help confirm the right part rather than a near-equivalent.
  4. Look at the sighting path while the head is off. Window condition, purge air, and whether the port faces a doorway or an outside wall — worth noting, because it explains a weak or unstable signal better than the tube usually does.
  5. Send the details with your enquiry. Model, reference or photographs; we come back with the matching tube and flag anything that does not look right before the order is packed.

Day-Blind Response

Day-blind is a property of the band, not a filter behind the window. A flame burns hot enough to give off ultraviolet well below 300 nm. Sunlight contains the same ultraviolet at the top of the atmosphere, but ozone removes almost all of it before it reaches ground level, so what arrives at a burner platform has effectively nothing left below about 290 nm. A tube that answers only between 185 and 260 nm has no daylight to answer to — the sun is simply not present in its band.

Indoors, in a permanently dark boiler house, that hardly shows. It shows where the detector can see daylight: an outdoor burner, a head mounted facing a doorway, a shed with the doors open in summer, or a sighting port that catches the sun for an hour in the afternoon. A tube with a wider response follows that light, and the detector reports flame when there is none — a fault that stalls a start-up sequence and sends someone to the panel with nothing obvious to find. Engineers who have chased it once tend to specify a UV tube for boiler flame detection with a day-blind response the next time.

None of this makes the detector immune to every light source. A welding arc on the same platform, or a neighbouring flame in the same sight line, can still reach the tube; the sighting tube, the purge air and the detector's own flame relay are what deal with those. Dirt and oil mist on the window absorb the flame's ultraviolet long before they affect daylight, which is why a weak signal is more often a dirty window than a failing tube.

And because the point is the band, a 185-260 nm UV tube is specified by spectral response rather than by shape. Two tubes can look identical in the hand and behave completely differently under a summer sun.

Tube Life & Handling

  • Changing a UV tube for boiler flame detection takes an hour; changing it after a failure costs a start-up. - Clean the window before you change anything. Oil mist, dust and boiler-house grime absorb ultraviolet at the window. A wiped window has brought back more weak flame signals than a new tube ever has. - Isolate the detector before the head comes off. Work to the plant's burner management procedure, not just the local isolator, and tell the control room the detector is out of service so the proving circuit is not left looking for a flame nobody can see. - Handle the tube by its base, with clean gloves. Grease and fingerprints on the envelope absorb the wavelengths the tube is trying to read. - Seat it square and take the cap fully home. A tube sitting at an angle, or a cap that is not closed, gives a signal that drifts with vibration — one of the commoner causes of intermittent flame loss at a burner front. - Keep spares sealed and dry. A tube left in its carton, dry and out of sunlight, is still good years later; one rattling loose in a drawer is not.

Specifications

ParameterValue
Spectral response185-260 nm
Tube typeDay-blind ultraviolet
Daylight responseUnaffected by sunlight
Operating temperature-20 °C to 60 °C
Expected service life25,000 hours
Tube componentsImported
FitsDetectors taking this tube reference, confirmed against your detector model
Typical dutyBoiler, furnace, kiln and incinerator flame detection

Ordering & Delivery

  1. Quote the detector model and the tube reference on the enquiry. Fitment is confirmed from those two lines, and a photograph of the old tube is the next most practical reference where the marking has gone. As a UV tube supplier we would rather ask twice at this stage than ship a tube that will not seat.
  2. Say how many you want to hold. Most plants take one to fit and one for the shelf. A tube ages in storage far more slowly than it does in a detector head, but there is little point stocking a case of them.
  3. Confirm how it travels. Tubes are packed individually in rigid cartons; tell your sales contact if the consignment has a long sea leg or a rough final delivery leg, so the packing matches the route.
  4. Agree the documents at the order stage. Commercial invoice, packing list and whatever your plant or customs broker requires are settled then, not after dispatch.
  5. Set the delivery date against the shutdown. Lead time moves with workload — confirm the current figure with your sales contact when you order rather than working from an older quotation.
  6. Check the carton before you fit anything. If a tube arrives damaged, photograph the carton and the tube and keep both; it is much harder to establish once the tube has been in a detector head.

Technical Support & Model Matching

Selection decides how well a part performs in service, so our engineers work through it with you. The team comes out of aviation and military ignition work, bringing 18 years of accumulated expertise to the designs we build. Send your operating conditions, a drawing or a worn sample; we help match the model, check interface details and flag anything that will not fit before you order. Because we manufacture in-house from core components through final testing, modifications stay under our control. Installation, commissioning and troubleshooting support continues after delivery.

FAQ

Will this tube react to sunlight?

No. A 185-260 nm UV tube responds only in the band below the point where the atmosphere cuts sunlight off, so daylight reaching the sighting port produces no flame signal. That is what makes it usable on outdoor burners, sun-facing detector heads and sheds with the doors open in summer. Daylight is not the only light that can reach a detector, though — a welding arc on the same platform or a neighbouring flame in the same sight line still can, and that is what the sighting tube and purge arrangement are there to control.

How do I find the right tube for my detector?

Start with the make, model and part number on the detector nameplate, then read the reference printed on the old tube or on the carton it came in. Those two together are enough in most cases. If the marking has rubbed away, send photographs of the tube from both ends and note the detector model; we check the combination and confirm it before the order is packed.

What are the signs that the tube is failing?

A tube on its way out usually gives warning rather than stopping dead: the flame signal falls, proving time lengthens, or the burner trips and relights on a second attempt. Compare against the signal value recorded at commissioning, then clean the window and check the sighting path before ordering a replacement — several weak signals turn out to be dirt rather than a tube.

Can our own technician fit it?

Yes. It is a sensing element inside the detector head, not a field-calibrated instrument: isolate the detector to the plant procedure, open the head, lift the old tube out and seat the new one square with the cap fully home, handling it by the base with clean gloves. What follows is a signal check with the flame on and off, which is part of normal detector proving rather than a tube adjustment.

Will it work on gas, oil and pulverised-fuel flames?

Flame ultraviolet in the 185-260 nm band comes from the combustion zone itself, so a UV tube for boiler flame detection behaves the same way on gas, light oil and most pulverised-fuel flames. Where the flame is heavily shrouded by a dense fuel cloud, or the sighting path is long and carries dust, tell us the fuel and the sighting arrangement — those conditions affect how much ultraviolet arrives at the tube far more than the tube's own response does.

What if the detector head runs hotter than the tube is rated for?

The tube is rated for -20 °C to 60 °C at the detector. If a head measures above that in summer, the cause is usually the head's own situation rather than the tube: hot casing radiating onto an uninsulated detector body, a missing heat shield, a sighting tube drawing radiant heat, or cooling air that has been turned down. Deal with that first — a tube run above its rating will not give the service life it is capable of, whatever the replacement.