TYH Ultraviolet Flame Detector (For torch)

TYH Ultraviolet Flame Detector (For torch)
- Powered by DC24V
- Includes both relay contacts at 2A/220V and a 4–20mA analog output
- Detects ultraviolet signals from a lighter flame up to about 4 metres
Download
View all downloads
  • TYH Ultraviolet Flame Detector (Flare Version),MY SHOP,TYH Ultraviolet Flame Detector (Flare Version)

Description

Product Overview

A flare stack only does its job when there is a flame at the top of it, and a pilot nobody can see is not proof of anything. The TYH ultraviolet flame detector turns that question into an electrical signal: it reads the ultraviolet light given off by a flame and reports flame-present or flame-out to the control panel, so an extinguished pilot shows up as an alarm instead of being noticed late.

The housing carries an explosion-protection marking for hazardous-area installation, which is what allows the detector to be fitted in the hazardous zone itself rather than at a distance in a safe area. Processing happens inside the body, and the result leaves through a switching output and a continuous analog output at the same time.

This UV flame detector flare version mounts on a bracket and is aimed at the flame zone instead of being screwed into pipework, so the body is lined up on the flame before the mounting is locked down. Sensitivity is set with push-buttons on the unit while the live value shows on the digital display.

As an industrial UV flame detector manufacturer we supply it to plant maintenance and instrumentation engineers, to the commissioning technicians who prove a pilot during start-up, and to the panel builders who assemble flare and burner control systems. On a burner it works alongside the ignition equipment that lights the flame, closing the gap between firing the igniter and confirming that ignition actually happened.

Specifications

ParameterValue
VersionFlare / torch version
Supply voltageDC24V
Relay output2 A / 220 V contacts
Analog output4–20 mA
SensingUltraviolet flame detection
Detection distanceAbout 4 m to a lighter flame
IndicationDigital display with live readings
AdjustmentPush-buttons on the body, internal microcontroller
Explosion protectionEXdⅡCT6 Gb
MountingFlat mounting bracket

Product Advantages

  • Mounted where the flame actually is. The housing is built for hazardous-area installation, so the detector can sit close to the flame. A short optical path also means a dirty window and a long sighting tube are not eating into the signal before it reaches the panel.
  • Two outputs from one device. A relay contact handles the switching side of the job, whether that is ignition enable, an alarm or a shutdown, while the analog output feeds a continuous flame reading to the controller. You get interlock proof and trend data without a second instrument and a second tapping point.
  • Set up on the unit, not in a laptop. Sensitivity is adjusted with the push-buttons on the body and the effect is visible on the digital display while you do it. Commissioning, a seasonal re-check and an on-shift tweak all happen at the detector itself.
  • Ultraviolet sensing follows the flame, not the surroundings. The detector responds to the ultraviolet light a flame gives off, so the signal tracks the presence of the flame rather than the temperature around it — which matters on a small pilot that can blow out quietly.
  • A bracket that lets the body be aimed. The mounting holds the detector at the sighting port and still allows the window to be lined up on the flame zone before the bolts are finally tightened, useful where the port and the flame are not on the same axis.
  • Built by an industrial UV flame detector manufacturer. This unit comes out of the same plant as the high-energy igniters, probes and ignition cables used on the same burner, so the side that lights the flame and the side that proves it are matched rather than bought from two suppliers who never speak to each other.

Installation & Commissioning

  1. Choose the sighting point. Position the flare stack burner flame detection sensor so the window looks straight at the pilot or flame zone with an unobstructed path, and leave enough room behind the body to reach the cap and the nameplate later.
  2. Fix the bracket. Bolt it to the structure or the port and leave the pivot free until the aim is right.
  3. Aim the window. Swing the body onto the flame zone and tighten the bracket once the reading responds.
  4. Bring the wiring back to the panel. Supply, relay circuit and analog loop all run to the control panel; route the analog pair clear of the ignition cable so a firing igniter does not put pulse noise on the measurement.
  5. Power up with no flame. Note what the display reads with the pilot out — that baseline is what everything afterwards is judged against.
  6. Light the pilot and set the sensitivity. Use the push-buttons to find a level where a lit pilot reads clearly as flame-on and a lifted flame reads as flame-out, then repeat the check once the installation is hot.
  7. Prove the outputs. Extinguish the flame and confirm the relay changes state at the panel and the analog reading follows it down instead of sticking.
  8. Record the settings. Write the sensitivity value, the date and the terminal numbers on the commissioning sheet; the next technician will need them more than you will.

Use Scenarios

  • Refinery flare tips. Vent gas can only be released once the pilot is proven lit. The UV flame detector flare version watches that pilot continuously and reports its state to the flare control panel, so a flame-out is seen before the gas is routed to the stack.
  • Burner pilot verification. The ignition equipment fires, the detector confirms, and the start-up sequence moves on. If no flame appears, the sequence stops rather than continuing to feed fuel into an unlit burner.
  • Emergency shutdown strings. The relay contact sits in the shutdown string, so losing the flame trips the sequence immediately instead of waiting for an operator to react to a screen.
  • Restart after a turnaround. Once the pilot is relit, the detector gives a positive reading before the plant returns to normal running, and the analog trend shows the flame settling rather than hunting.
  • Sites with nobody standing at the flare. Where the stack is remote or unmanned, the detector is the only continuous proof that the flame is still burning.
  • Skid and panel builders. Integrators assembling a burner management or flare skid fit the detector and land both outputs in their own panel before the skid leaves the workshop.

Outputs & Control Integration

The detector reports two things at once, and they answer different questions.

The relay contact answers is there a flame? It changes state when the flame state changes, and it is the output that goes into a burner management input, an alarm annunciator or the shutdown string — anywhere the panel wants a clean contact rather than a value. Wire it where the interlock logic already expects a flame-proven signal.

The analog output answers how strong is the flame? It carries flame intensity as a continuous current, so a controller or trend screen sees the signal weakening before the flame finally drops out. That is what makes the detector useful for maintenance as well as for interlocking: a pilot whose reading has been sliding for a week is usually a pilot that needs attention.

Both are live at the same time, so an existing panel needs one digital input and one analog input — or only the digital input if no analog channel is free. No proprietary protocol sits between the detector and the panel and no separate controller has to be bought. On a flare line-up the flare stack burner flame detection sensor typically feeds the flare panel's pilot-proven logic through the relay and the trend screen through the analog loop.

One point worth settling with your instrumentation team before commissioning: agree what the panel should do if the detector loses supply, then check that decision against the way the relay logic has been wired.

Custom Builds & Ordering

  1. Describe the duty. Tell us where the flare stack burner flame detection sensor will sit — flare tip, pilot or torch — what the sighting distance is and what the flame is burning, so the build suits the job rather than the other way round.
  2. Confirm the mounting. The flare version uses a flat bracket. If your port is threaded, or you are matching an existing coupling, say so at this stage, because that is a different mounting arrangement and it changes the build.
  3. Send what is being replaced. A photograph of the old nameplate plus the existing wiring saves a round of questions, particularly on a like-for-like swap during a shutdown.
  4. Confirm the signals the panel expects. Relay only, analog only, or both on separate cards — the answer decides the terminal arrangement you receive.
  5. Raise non-standard work early. Mounting arrangement, output configuration, marking and batch size can all be reviewed by our engineering team, and a change agreed before the build starts costs far less than one discovered at commissioning.
  6. Agree packing and freight. Units are packed for export and travel by air or sea; confirm the packing your site needs and who is handling the import documents.
  7. Confirm lead time against your shutdown date, and ask for the explosion-protection documents your site requires so they arrive with the unit. Quantities, price and delivery terms are confirmed with your sales contact for each order.

Technical Support & Model Matching

Not every buyer arrives knowing which item in the range fits. Tell us what the part has to do, the space it goes into and the supply you have, and our engineers check it against the specifications we publish and tell you which model matches — and when a standard item will not do. The same team designs, builds and tests the products in our own plant in Shaanxi: 28 people, 16 patents, national high-tech enterprise status, in business since 2018. They answer questions before you order, stay reachable afterwards for fitting questions and fault-finding, and take custom or non-standard requests directly.

FAQ

What installation options are available for the TYH Ultraviolet Flame Detector?

The UV flame detector flare version is supplied with a flat mounting bracket: the bracket holds the body at the sighting port and its pivot lets you line the window up on the flame zone before the bolts are locked down, which suits a detector aimed at a flare tip, a pilot or a torch. If your installation ends in a threaded port — a coupling, a valve or a cooling-air connection — a threaded mount is the correct arrangement instead of the bracket, and that is a separate build.

Can the detector be integrated with existing combustion control panels?

Yes. The relay contact goes to a digital input for flame-proven logic, an alarm or a shutdown, and the analog output goes to an analog card or a trend screen. Both are available at the same time, so a panel that already uses a flame switch can take the relay alone and add the analog signal later without changing the detector. No proprietary protocol sits between the detector and the panel.

Do you provide customization for flame detectors and related ignition equipment?

Yes. As an industrial UV flame detector manufacturer we build non-standard units for plant projects — different mounting arrangements, output configurations, marking and batch quantities to suit a particular installation. Send the drawing, the site conditions or a photograph of the part being replaced, and our engineering team will confirm what can be adapted and what should stay standard.

What maintenance or calibration support do you offer for ultraviolet flame detectors?

We support diagnostics, calibration and tuning of the detectors we supply. In practice that means guidance on setting and re-checking sensitivity with the push-buttons and the digital display, help with a signal that has drifted or become erratic, and advice on how often the window and the aim should be checked on your installation. Most drift traces back to a dirty window or a bracket that has moved, and both are quick to rule out.

How far can the detector see a flame?

The published figure is about 4 m to a lighter flame, which is a deliberately small reference flame. A real pilot is larger, so in service the working distance is usually governed by sighting conditions rather than flame size: a clean window, a clear optical path and a bracket that has not shifted matter more than the last few centimetres. Check the reading at commissioning and again after the first month.

How is the flare version different from the boiler version?

They share the same detection principle, supply and output set; the difference is the mounting. The flare version fixes to a flat bracket and is aimed at the flame zone, which suits flare tips, pilots and torches. The boiler version uses a threaded connection so it screws onto existing pipework, a coupling or a cooling-air connection at the burner. Tell us what your port looks like and we will confirm which build to supply.

Is the detector suitable for a hazardous area?

The housing is marked EXdⅡCT6 Gb, which is what allows it to be installed in the hazardous zone at the flare tip or the burner front instead of in a safe area at a distance. If your site needs the protection documentation before the unit is accepted, ask for it with the order so it arrives with the detector rather than after it.