TYH Ultraviolet Flame Detector (Boiler Version)

- Runs on DC24V
- Sends outputs via relay contacts, 2A/220V, plus an analog 4–20mA signal
- Picks up a lighter’s ultraviolet flame at a distance of 4 metres
- Microcontroller deals with signals inside, adjustable by pressing buttons. You get both real-time data on the digital display and external outputs
Download
View all downloads
  • TYH Ultraviolet Flame Detector (Boiler Version),MY SHOP,TYH Ultraviolet Flame Detector (Boiler Version)

Description

Product Overview

The UV flame detector boiler version watches the burner flame through a threaded port on the boiler front and reports what it finds to the burner control panel. It runs on DC24V and leaves the enclosure with two independent signals: a relay contact rated 2 A at 220 V, and a 4–20 mA analog output. A microcontroller inside handles the signal processing, real-time numbers appear on the digital display, and the buttons on the unit let a fitter trim the response on site without a laptop.

The connection is what makes this the boiler version. A threaded body screws onto the common couplings, valves and cooling-air pipes already fitted around most boiler sighting ports, so replacing a scanner usually means unscrewing the old unit and screwing this one in — no new bracket, no cut-out, no re-machined port. Where the old detector hung off a flat bracket instead, the flare version of the same detector is the one that fits.

Fitters know the unit by its red cylindrical housing and the specification nameplate on the side; the metal threaded base and the side hex plug are what they work with during fitting. Combustion engineers specify it for new boiler builds and burner retrofits, maintenance teams keep one on the shelf as a spare, and integrators wire it into the panels they assemble for a boiler house.

It suits boilers that need a definite answer at light-off: flame proved before the fuel valve opens, and flame loss signalled before the furnace fills with unburnt fuel.

Boiler-Side Mounting & Connection

  1. Measure the port first. Note the thread form and size on the coupling, valve or cooling-air pipe the old scanner sat on, and photograph it together with the boiler make and model. Threads differ between boiler makers; a UV flame scanner supplier who checks your photograph before the unit is built saves you finding the mismatch at the boiler front.
  2. Look through the port before fitting anything. The view should take in the root of the flame, not the far wall or a patch of refractory, and nothing should sit between the window and the burner.
  3. Settle the cooling-air question. Where the port already has a cooling-air pipe, keep it in service — it cools the front of the unit and helps hold the window clear. If the port never had one, describe the furnace temperature and the port position and we will advise.
  4. Thread the unit in. Seat it with the sealing method the port uses, bring it up firm by hand, and finish on the hex with a wrench — never by turning the housing.
  5. Wire it through the cable entry: DC24V in, relay contacts out, 4–20 mA pair out, and the signal cable routed away from ignition high-voltage leads and drive cables.
  6. Power up and watch the display. Light the burner, let the reading settle, and set the response with the buttons against a steady flame rather than during the first seconds of light-off.
  7. Write the settings down. Record the port, the date and what you set, and keep the note with the boiler maintenance file for the next replacement.

Detection Performance & Adjustment

The detector picks up a lighter's ultraviolet flame at 4 metres, which is the figure to plan a sighting run around. A lighter is a small, weak source at that distance; a burner flame is a far larger one, but the optical path still decides what reaches the sensor — the length of the sighting tube, how clean the window is, and whether steam, dust or the shape of the flame cuts across the line of sight. In an industrial boiler flame safety monitoring system the useful question is not the number on a datasheet but whether the port gives an uninterrupted view of the flame root, and that is settled at the boiler front.

Because the detector works on the ultraviolet output of the flame rather than on visible brightness, a glowing firebrick or a hot furnace wall does not read the way a flame reads. It answers to what the flame itself emits in the ultraviolet band.

Inside, a microcontroller does the processing and the buttons shift the response to suit the installation — a long, dirty sighting path needs a different setting from a short, clean one. The digital display shows real-time numbers throughout, which is what makes commissioning practical: you can watch the reading rise as the burner lights, settle as the flame steadies, and see exactly what the detector is being given before you hand the interlock over to it.

Adjustment is a matter of watching a steady flame and setting the point where the detector holds reliably, not the point where it only just triggers. A setting that works on a good day will trip the boiler on a humid one.

Signal Outputs & Control Integration

  • Relay contact, 2 A at 220 V. The contact carries flame-present and flame-absent to the burner management system or to a panel relay. Use it for the interlock logic; if the panel has to switch a large contactor or a motor, let an interposing relay take that duty instead of the detector's contact.
  • 4–20 mA analog output. A continuous reading of what the detector sees, wired to a DCS input card, a recorder or a panel meter. Trended over weeks it is the cheapest diagnostic on the boiler: a slow fall in current is usually the window starting to coat, long before the reading is low enough to matter.
  • Two outputs, two different jobs. The relay answers “is there flame”; the analog channel shows how healthy the view is. Bringing both back means an operator can watch the signal drift while the interlock still does its work.
  • Keep the analog pair away from noise. Shielded twisted pair, earthed at the panel end only, routed apart from ignition high-voltage leads and drive output cables. A detector sitting in the same tray as an ignition lead will show every spark on the analog channel.
  • Prove the wiring before the fuel train is enabled. Light a source at the port, confirm the contact changes state at the terminals, and read the mA value at the input card. Finding a crossed pair then takes five minutes; finding it during a start-up does not.
  • Draw the as-built. Note which terminals the relay and the analog pair land on and leave the drawing in the panel. The next technician will not be you.

Specifications

ProductUV flame detector boiler version
Supply voltageDC24V
Output 1Relay contacts, 2 A / 220 V
Output 2Analog 4–20 mA
Detection rangeLighter flame up to 4 m
Signal processingInternal microcontroller
AdjustmentPush buttons on the unit
IndicationDigital display, real-time readings
MountingThreaded connection for couplings, valves and cooling-air pipes
Explosion protectionEXdⅡCT6 Gb
BodyCylindrical housing with metal threaded base and side hex plug

Explosion Protection & Hazardous Areas

The EXdⅡCT6 Gb marking on the nameplate tells a hazardous-area assessor what the enclosure was built to: flameproof construction for group IIC gases, temperature class T6, equipment protection level Gb. In plain terms, the enclosure is designed to contain an internal ignition instead of letting it escape into the surrounding atmosphere, which is why the joints, the cover fixings and the cable entry are part of the protection rather than just packaging.

That makes it the right detector for boiler fronts inside a classified area, for fired heaters in refining and petrochemical units, and for coking or coal-chemical plant where the burner port sits in a gas-hazardous zone. Where the boiler front is unclassified the same detector still does the job; the marking simply is not the deciding factor there.

Handling rules matter as much as the marking. Do not file, machine, paint or scrape the flamepath faces while cleaning or fitting, keep the joint faces clean and undamaged, use the cover fixings the enclosure came with, and bring the cable in through a certified gland suited to the enclosure. Never open the cover while the area is live.

For the plant file, keep the two things separate: the zone classification belongs to your site, and the hardware is limited to what its marking covers. A unit that has been dropped, dented or opened for repair should be replaced rather than returned to service, because the protection depends on the enclosure being exactly as it left the factory.

Boiler Applications & Operating Scenarios

  • Utility and captive power boiler fronts. Main burner proving through the existing sighting port, with the relay feeding the burner management system and the analog channel going to the plant trend. Maintenance teams change a failed scanner here with the boiler on its run-down cycle, which is where the threaded fit earns its keep.
  • Packaged industrial boilers on gas or heavy oil. Start-up burner and main flame proving on the same port, with the detector acting as one permissive input in an industrial boiler flame safety monitoring system. Commissioning engineers set the response at the first light-off and rarely touch it again.
  • Retrofits where the old scanner has gone dark. The usual job: an ageing detector that no longer holds a signal and a port you would rather not modify. Confirm the thread from a photograph and the swap stays mechanical instead of becoming a fabrication job.
  • Biomass, waste-heat and incineration boilers. Dust, radiant heat and a bright furnace background make the optical path the weak point. Cooling air and a cleaning interval matter more here than the model number, and the analog output tells you when the window needs attention.
  • Refining, coking and coal-chemical fired heaters. Where the burner port is threaded and the area is classified, the explosion-protected enclosure is what allows the detector to sit at the burner instead of behind a window in a safe area.
  • Boiler houses with frequent start-stop cycling. Every light-off tests the setting. The display and the analog trend let the shift team see a detector drifting before it costs them a trip.

Maintenance & Care

Routine work on the detector is almost entirely about the window. How often it needs cleaning depends on the fuel, the dust loading and whether cooling air is connected; start with a monthly look at the reading and let the trend set the interval from there. A pulverised-coal or biomass boiler will want attention more often than a gas-fired packaged unit, and a boiler that runs continuously will teach you more in a month of analog trend than any schedule written on paper.

Clean the window with a soft cloth and a solvent that will not attack the glass or the paint, never with a scraper or an abrasive. While the unit is out, check that the sighting tube is clear and that nothing has been left in the port after work on the burner. Re-seat it in the same position and confirm the reading returns to where it was before you started.

Watch the 4–20 mA signal for drift rather than waiting for a trip. A slow decline over weeks is normally fouling; a sudden step is normally a wiring or supply problem; a reading that jumps while the burner is steady usually means the aim has moved or combustion has changed.

Do not open the enclosure while the area is live, and do not file or scrape the flamepath faces when cleaning the threads. If the detector has been damaged, replace it — a repaired flameproof enclosure no longer carries the protection it was built with.

Keep one spare detector set to the same configuration, with the settings written on the maintenance sheet, so a failed unit becomes a changeover rather than an investigation.

Ordering & Delivery

  1. Send the port details: thread form and size, the coupling or valve it sits on, whether a cooling-air line is fitted, plus a photograph and the boiler make and model.
  2. Confirm the supply and the outputs your panel will use — DC24V, the relay contact, the 4–20 mA channel, or all of them.
  3. State where the detector will be installed and how that area is classified, so the explosion protection on the nameplate can be checked against it before the order is accepted.
  4. Say at the order stage what else has to travel with the unit for your plant's hazardous-area file, so nothing has to be chased after delivery.
  5. Confirm lead time, packing, shipping terms and payment terms with your sales contact. All of these depend on the destination and the quantity, and they are confirmed per order.
  6. Hold the port record and the settings with the maintenance file. Ordering again from the same UV flame scanner supplier with that record attached keeps the second unit identical to the first.

Technical Support & Model Matching

Not every buyer arrives knowing which item in the range fits. Tell us what the part has to do, the space it goes into and the supply you have, and our engineers check it against the specifications we publish and tell you which model matches — and when a standard item will not do. The same team designs, builds and tests the products in our own plant in Shaanxi: 28 people, 16 patents, national high-tech enterprise status, in business since 2018. They answer questions before you order, stay reachable afterwards for fitting questions and fault-finding, and take custom or non-standard requests directly.

FAQ

Can this detector go straight onto the port my old scanner used?

In most cases, yes. The threaded connection is made for the couplings, valves and cooling-air pipes that surround boiler sighting ports, so a replacement usually screws onto what is already there. The thread is the deciding detail — send a photograph of the port with the boiler make, and we will check the unit against it before it is built. It is worth doing: an industrial boiler flame safety monitoring system is judged on how reliably it proves flame at light-off, and a detector that does not seat squarely on the port cannot see the flame root properly.

What is the difference between the boiler version and the flare version?

Mounting, mainly. Both run on DC24V, both give a relay contact plus a 4–20 mA output, and both use a microcontroller with a digital display and button adjustment. The UV flame detector boiler version fixes by thread to couplings, valves and cooling-air pipes on a boiler front. The flare version uses a flat mounting bracket for a flare stack or pilot where there is no threaded port to screw into. The port decides which one you need.

Do I need to run cooling air to the detector?

It depends on the port and the furnace. Cooling air keeps the front of the unit cooler and helps hold the window clear, which matters most on solid-fuel, biomass and waste-heat boilers where radiant heat and dust arrive together. If the port already has a cooling-air connection, keep it in service. If it never had one, tell us the furnace temperature and how the port is positioned and we will say whether your installation needs it.

Will it run from the 24 V supply already in my panel?

The detector is built for DC24V. Check that the panel's 24 V rail can carry it alongside everything already connected, and that polarity and earthing match your drawing. Where the panel uses 110 V or 220 V control, keep the detector on 24 V and let the relay contact do the switching between the two voltages.

Can it be adjusted on site without software?

Yes. The response is set with the buttons on the unit, and the digital display shows real-time readings while you do it, so a fitter can watch the numbers move as the burner lights and settles. Set it against a steady flame rather than during the first seconds of light-off, and write the final setting on the maintenance sheet — that note is what turns the next replacement into a quick changeover.

What does the EXdⅡCT6 Gb marking allow, and what paperwork should I ask for?

It describes a flameproof enclosure for group IIC gases at temperature class T6, equipment protection level Gb — the level generally required for Zone 1. What it does not do is classify your area; that assessment belongs to your plant. Ask for the certificate copy with the order so it can go into the area file, and check it against the zone drawing before installation. Once fitted, the protection depends on the enclosure staying as it was built: no filing or painting of the joint faces, the original cover fixings, and the cable brought in through the entry it was designed for.