Semiconductor Ignition Plug TYZ-116 Adopts an integrated design of ignition cable and semiconductor spark plug

Semiconductor Ignition Plug TYZ-116
Pushes out a high-voltage DC pulse directly to its ceramic tip, designed for powerful electron breakdown to ignite, and doesn't bother much with changing environmental conditions
Integrated seamlessly with both cable and the ignition plug as a unit
Connection uses a tie-wire fuse, keeping things in place during repeated ignition cycles
Download
View all downloads
  • Semiconductor Ignition Plug TYZ-116,MY SHOP,Semiconductor Ignition Plug TYZ-116

Description

Product Overview

The TYZ-116 semiconductor ignition plug lights industrial burners and furnaces from a high-voltage DC pulse, with no pilot flame and no moving parts. The pulse runs down an ignition cable that is built into the plug as one piece and breaks down across a semiconductor-glazed ceramic tip, throwing a spark into the fuel and air at the burner throat.

That single-unit construction is the point of the design. Nothing is crimped or screwed together on site, so the termination that most often fails on a burner — the place where a cable meets a separate plug — does not exist as a joint the fitter has to make. The plug threads into the port, holds its depth, and stays there through the run instead of being pulled once the flame is established.

We build the TYZ-116 ignition plug for industrial burner and furnace ignition, working with maintenance and reliability teams at boiler, furnace and process-heater plants and with the burner OEMs that supply them. It suits installations where ignition is expected to work first time, every start, without an electrode gap to re-check between shifts.

Ignition Cycle Sequence

  1. The igniter control releases a high-voltage DC pulse into the cable. Because the cable is built into the plug, the pulse never crosses a field-made joint on its way to the tip.
  2. The pulse reaches the strike face, where a semiconductor glaze covers the alumina ceramic. The glaze spreads the charge across the face instead of crowding it onto one sharp metal point.
  3. The surface breaks down and the spark jumps across the glazed ceramic, igniting the fuel and air mixture at the burner throat.
  4. The flame detector confirms the flame and the control stops the pulse train. The plug then sits in the flame path doing nothing until the next call for heat.
  5. On the next start the discharge repeats over the same path at the same energy. Ignition quality does not drift between inspections the way it does on a gap-style igniter, because there is no gap to widen and no electrode to re-gap.
  6. Chamber conditions — pressure, humidity in the combustion air, dust, and the normal swing of furnace temperature — have little influence on where the breakdown happens, so the spark stays consistent as plant conditions change through the day.

Construction and Materials

The strike face is high-purity alumina ceramic with a semiconductor glaze fired onto it. Alumina is used here because it keeps its shape and its electrical resistance at burner temperature; a lower-grade ceramic begins to conduct when it is hot, and the spark then tracks across the surface instead of breaking down where the burner needs it. The semiconductor glaze is part of the ceramic rather than a separate fitted part, so there is no tip joint to loosen.

The electrode and internal parts are high-temperature alloy, not a general-purpose steel that softens after a few hundred cycles. Everything sits inside a one-piece stainless steel body, and the ceramic is bonded to that body with high-temperature glass adhesive. That glass is the seal: it keeps combustion gas and plant moisture away from the internal parts and keeps its grip as the plug heats and cools.

A single piece of stainless also means no seam for condensate to collect in and no plated surface to break down at temperature. The thread is cut into the same body that carries the ceramic, so the seating face and the strike face stay in line. Because the ceramic and the assembly on every TYZ-116 semiconductor ignition plug are held to our own specification, the material grade stays the same from one batch to the next.

Connection Lock and Cycle Duty

  • Tie-wire fuse at the coupling. After the cable is mated, a steel wire is tied through the connector so vibration from the burner front and repeated heating cannot walk the joint loose. On a plug that fires several times a shift, that is the difference between a connection that stays put and one that needs re-seating at every shutdown. - Seating that holds its depth. The plug threads in and stays where it was set, so the strike face keeps the position the burner was designed around instead of drifting closer to or further from the fuel stream. - A seal that absorbs thermal movement. Metal and ceramic expand at different rates; the high-temperature glass bond between them takes up that movement rather than letting it open a path for gas or moisture. The TYZ-116 ignition plug for industrial burner and furnace ignition is built around that pattern rather than around continuous duty. - Headroom above the working temperature. Start-up and upset conditions push a chamber past its normal temperature for short periods, and the body and seal are rated for excursions above the continuous figure shown in the specification table. - Inspection without removal. The strike face can be checked through the port at a shutdown and the fuse wire tested by hand, so a technician can confirm the plug is sound without taking the assembly out of the burner.

Applications

  • Package boilers on daily start-stop. The TYZ-116 semiconductor ignition plug lights the main flame directly at each start, so the burner does not depend on a pilot that has to be proved before the main valve opens.
  • Petrochemical process heaters and fired furnaces. Here the plug works inside a chamber that is under pressure and hot for weeks at a time, and it stays mounted through the run rather than being withdrawn after light-off.
  • Heat-treatment, annealing and reheat furnaces. These follow the production schedule, which means many light-offs between overhauls; the threaded seat and fused connection are what keep the ignition point stable across those cycles.
  • Kilns, incinerators and biomass burners. Dirty combustion air and a particulate load are normal in this duty, and the glazed face is the part that has to keep breaking down cleanly.
  • Burner OEM builds and retrofits. The TYZ-116 ignition plug for industrial burner and furnace ignition is specified on new burner assemblies and on retrofits where an older gap-style igniter is being replaced; thread, reach and cable route are settled before the order.
  • Test rigs and laboratory burners. Where ignition has to repeat identically test after test, a plug with nothing to adjust is easier to keep in calibration.

Specifications

Alumina content95%
Tip constructionSemiconductor glaze fired onto high-purity alumina ceramic
Electrode and internalsHigh-temperature alloy
BodyOne-piece stainless steel
SealHigh-temperature glass adhesive
CableIntegrated with the plug as one unit
Connection lockTie-wire fuse
Discharge voltage700–1000 V DC
Continuous temperature-60 °C to 800 °C
Short excursionsup to 1300 °C
Pressure ratingup to 16 MPa
MountingThreaded

Fitment and Ordering

  1. Read the marking on the plug you are replacing. A photo of the number on the body is usually the quickest identification and saves a round of questions.
  2. Measure the thread and the reach — the distance from the seating face to the tip. Thread diameter, pitch and reach decide whether the strike face lands in the right place in the burner throat.
  3. Check the seat: flat face, spot-faced, or recessed into a boss. A plug that seats on the wrong face sits at the wrong depth even when the thread matches.
  4. Work out the cable run. Because cable and plug arrive as one unit, the length and the route through the burner casing have to be agreed at order rather than improvised on site; if the run is unusual, raise it in the enquiry and availability is confirmed with the quotation.
  5. Send a photo of the worn plug beside a rule and one of the burner port. We check the fit against the drawing before the order is released.
  6. Confirm quantity — one for the burner plus a shelf spare is the usual pattern on a cycling unit, and it is cheaper than a second shutdown.
  7. Confirm packing, lead time, payment terms and shipping documents with your sales contact. These are quoted per order and are not published on this product.

Technical Support & Model Matching

Selection decides how well a part performs in service, so our engineers work through it with you. The team comes out of aviation and military ignition work, bringing 18 years of accumulated expertise to the designs we build. Send your operating conditions, a drawing or a worn sample; we help match the model, check interface details and flag anything that will not fit before you order. Because we manufacture in-house from core components through final testing, modifications stay under our control. Installation, commissioning and troubleshooting support continues after delivery.

FAQ

Which ignition control will drive this plug?

It runs from a high-voltage DC pulse, the same kind of output a semiconductor-style igniter already provides. Tell us the igniter or control panel model in use and, as a semiconductor ignition plug supplier, we will check its discharge range against the plug before you order. The plug needs a pulse inside the range listed under Specifications; a low-voltage automotive-style coil output will not drive it.

Is the ignition cable included, or can I reuse the one already on the burner?

The cable and plug are supplied as one unit, and the plug is not sold as a bare body for fitting to an existing cable. That is deliberate, because the cable-to-plug termination is the part that fails first in service. Give us the route length and the connector type at the control end when you enquire so the unit arrives ready to fit.

Does it matter which way up the plug is mounted?

No. Vertical through a top plate, horizontal through a side wall or inverted under a furnace floor all work, because the body is sealed and the thread holds the tip at the set depth. The two things to watch are that the seating face lands squarely on the port and that the cable leaves the plug without a hard bend against the casing.

How do I look after the strike face between shutdowns?

Wipe soot and carbon off the glazed face with a soft cloth and check that nothing has bridged the ceramic. Do not scrape it with a wire brush or an abrasive pad — the glaze is the working surface, and once it is cut through the spark no longer breaks down where it should. Erratic ignition on a plug that is otherwise intact is usually carbon on the face rather than a failed plug.

What happens if the ceramic gets chipped?

Replace it. A chip or a worn patch in the glaze moves the breakdown point and changes the spark energy, so the plug may still fire in open air and then misfire inside the chamber. Treat the tip as the fragile part whenever the plug is out of the burner, and keep it in its packing until it goes in.

Can it be used in wet or dusty plant air?

The glass bond between the ceramic and the stainless body is there to keep moisture and dust out of the plug, and the strike face works in humid combustion air and dirty flue gas. Keep the connector end clear of standing water and route the cable where it will not lie in a puddle or rest against a hot casing.

CONTACT US

If you have any queries, get in touch today! Don't hesitate. We try to take the extra step for our customer satisfaction.
Name
Email*
Message
Verification Code*
Click to verify
Leave a message
Name
Email*
Message
Verification Code*
Click to verify