• Plasma Ignition Nozzle,MY SHOP,Plasma Ignition Nozzle
  • Plasma Ignition Nozzle,MY SHOP,Plasma Ignition Nozzle

Plasma ignition electrode for igniting hard-to-ignite substances

Plasma Ignition Nozzle
How it works: When activated, plasma forms at the front, creating a 50 mm plasma torch
Design: The rear section has two ports—one for the power and one for compressed air
Materials: Outside tube is stainless steel while the inside uses ceramic as an insulator S
Download
View all downloads
  • Plasma Ignition Nozzle,MY SHOP,Plasma Ignition Nozzle

Description

Product Overview

This plasma ignition nozzle for industrial burner ignition is the torch end of the ignition system. Mounted in the burner port, it takes high-voltage power and compressed air at the rear and releases a plasma torch at the front — a hot, electrically conducting jet that lights a fuel a spark would leave cold.

It exists for the difficult starts. A cold furnace, a heavy oil that atomises badly, a process gas whose heating value drifts with plant load, a port set deep in the throat: in each of those the burner can take several attempts before it holds a flame, and the ignition source is usually the reason. A plasma torch gives that start a heat source with real length behind it, and it does the work from the two connections at the back of the nozzle.

On most installations the nozzle is the part that gets changed at a shutdown. A new one restores the start-up without touching the power unit, the ignition cable or the control panel, which is why the part is kept identifiable and replaceable rather than sealed into the burner.

Burner ports are drilled to their own drawings, so a nozzle is rarely a stock item. We are a custom plasma ignition components manufacturer, and each nozzle is built to the drawing, sketch or worn part you send rather than to a catalogue number.

Operating Principle

  1. Power reaches the rear power port from the ignition unit, carried on the high-voltage cable.
  2. Compressed air enters the second rear port and runs along the tube to the front of the nozzle.
  3. At the front face the voltage breaks down across the plasma ignition electrode and the nozzle body, and the air passing through that arc is heated into plasma.
  4. The plasma leaves the front as a long torch, carrying heat well past the metal face instead of confining it to a single point.
  5. That jet reaches the fuel and air where they meet at the burner throat, and lights a mixture a short spark would fail to hold.
  6. Once the flame is established, ignition stops and the burner's flame detector takes over supervision; the nozzle has done its job for that start.

Construction and Materials

Outside, the body is a stainless steel tube, chosen because it holds its surface in the radiant heat around a burner throat instead of scaling the way mild steel does. Inside, a ceramic insulator surrounds the electrode and holds it away from the tube wall, so the discharge forms at the front face where the torch is wanted rather than against the metal.

The air branch is welded to the body and ends in a push-to-connect fitting — a deliberate choice for a plasma ignition nozzle that is changed during a shutdown. The line pushes on and seals, and it releases again without a spanner on the tube. At the mounting end, a hex nut and a brass collar sit behind the threaded male end; that is the fixing that holds the nozzle square in the burner fitting.

Because the working air passes through the body on every start, the face stays purged between cycles. There is no fan port on this part: the air that makes the plasma is also the air that keeps the front clear.

Check the ceramic whenever the nozzle is out of the port. Cracks, chips and an eroded front face are the signs that it is near the end of its service — a nozzle that still screws in cleanly but shows those marks will light the burner intermittently and then not at all.

Burner Port Matching

  • Read the port first, the part list second. Three ignition families are built for industrial burner ports here, and what sits at the port — a compressed-air line, a flange face or a threaded boss — tells you which family the burner was designed around before any model number is quoted.
  • Compressed air plus a high-voltage lead means a plasma ignition nozzle for industrial burner ignition. Two rear ports, a stainless tube and a ceramic-insulated plasma ignition electrode at the front, projecting a long torch. If the part coming out of the port carried an air fitting, stay in this family and match the thread, reach and port layout.
  • A flange face with no air connection supports a semiconductor electrode nozzle such as the TYZ-100: glazed ceramic front end, 95% alumina with a high-temperature alloy and glass seal, one-piece stainless body, flange installation, 700–1000 V, 5 MPa, -60 °C to 800 °C with short excursions to 1300 °C. It strikes its arc across the ceramic face and needs no air stream to do it.
  • A threaded boss carrying a fixed cable supports a semiconductor spark plug. TYZ-172 and TYZ-171 are rated to 5 MPa, TYZ-173 and TYZ-116 to 16 MPa; all four discharge at 700–1000 V and run from -60 °C to 800 °C, with short excursions to 1300 °C where the plug is specified for them. Between siblings, pressure class and mounting decide the choice, not voltage.
  • Identify the old part by its front end rather than its body. An open metal tube with a gas path is a plasma nozzle; a glazed ceramic disc on a flanged body is an electrode nozzle; a ceramic tip on a hex-bodied plug with a moulded-in cable is a spark plug.
  • If the plant cannot bring dry, oil-free compressed air to the burner port, plan for a semiconductor part instead. The discharge in a plasma nozzle has nothing to form a torch from without that air, and the burner will behave as though the new part were dead.
  • Confirm the fit with measurements, not with a name. Send photographs of the port and of the old part beside a rule, plus thread or flange dimensions, working pressure and the temperature the port sees. As a custom plasma ignition components manufacturer we build to the ratings above, but the interface has to come off your burner.

Fuels and Burner Applications

  • Cold furnace start-up — the first light-off after a shutdown, when the furnace is below the temperature that keeps a flame stable, is the hardest start of the day.
  • Heavy and residual fuel oils — a fuel that atomises badly when cold needs an ignition source with more heat and more length than a spark can give.
  • Weak or shifting process gas — low-heating-value gas and blends that change with plant load are the case a plasma ignition nozzle for industrial burner ignition is usually bought for.
  • Ports set deep in the throat — where fuel and air meet well beyond the reach of a short electrode, the projected torch closes the distance.
  • Boilers, process furnaces, kilns and thermal oxidisers — burners that must light on demand and stay lit through load changes.
  • Replacement on an existing plasma installation — a worn nozzle comes out and the new one goes onto the same port, power lead and air line.

Specifications

PropertyValue
Outer bodyStainless steel tube
Internal insulationCeramic
Plasma torch projection50 mm
Working mediumCompressed air
Air connectionRear port, push-to-connect fitting
Power connectionRear port
Air branchWelded to the body
MountingThreaded male end with hex nut and brass collar
Fuel rangeHard-to-ignite fuels
Typical dutyIndustrial burner and furnace ignition

Commissioning on the Burner

  1. Check the port first: thread form, depth, and the distance from the mounting face to the point where fuel and air meet.
  2. Decide where the tip should sit. A nozzle set too deep behind a lip or a refractory ledge will light the burner late, or not at all.
  3. Screw the nozzle in on the threaded male end and tighten on the hex nut so the brass collar seats against the burner fitting.
  4. Push the compressed-air line onto the rear fitting and tug it lightly to confirm it has locked.
  5. Connect the power lead to the second rear port and route it clear of hot surfaces and sharp edges.
  6. Bring the air up before the first attempt. Without the air stream the discharge has nothing to turn into plasma, which is a common reason a new nozzle appears dead.
  7. Make a short trial start and watch the flame signal on the panel rather than the flame itself. If light-off is late or the signal is weak, adjust tip depth or air flow before touching the power side; most first-start problems sit on the air and the position, not on the electrics.
  8. Record the tip depth and the air setting that gave a clean light-off, so the next replacement starts from a known position instead of from scratch.

Ordering and Delivery

  • Port details — a drawing, a marked sketch or the worn nozzle itself. Thread, depth, tip position and the arrangement of the two rear ports are what the replacement is built around.
  • Fuel and burner — tell us what the burner fires and where the nozzle sits, because that sets how much of the torch has to leave the nozzle.
  • Quantity — state how many burners you are covering and whether you want a spare on the same order; the order quantity is confirmed on the quotation.
  • Lead time — confirmed per order once the drawing and quantity are fixed; ask your sales contact for the current schedule.
  • Packing — the tip and the air fitting are protected for transport, and the packing method is confirmed when the order is placed, including for sea freight or air freight.
  • Documents — confirm the invoice, packing list and any inspection document the receiving plant requires before shipment.
  • Payment and shipping terms — confirmed with your sales contact at the time of order.

Technical Support & Model Matching

Selection decides how well a part performs in service, so our engineers work through it with you. The team comes out of aviation and military ignition work, bringing 18 years of accumulated expertise to the designs we build. Send your operating conditions, a drawing or a worn sample; we help match the model, check interface details and flag anything that will not fit before you order. Because we manufacture in-house from core components through final testing, modifications stay under our control. Installation, commissioning and troubleshooting support continues after delivery.

FAQ

Which fuels can this nozzle ignite?

It is built for hard-to-ignite fuels: heavy and residual oils that atomise poorly when cold, low-heating-value or variable process gas, and burners where the mixture at the throat is too cold or too lean for a spark to hold. If the burner currently needs repeated attempts or a rich pilot before it stays lit, this plasma ignition nozzle is the part that changes the start-up. Tell us the fuel and where the nozzle sits, and the tip position is set to suit it.

How far does the plasma torch project, and what decides where the tip sits?

The torch leaves the front face as a jet long enough to pass the lip of a burner throat and reach the fuel and air where they meet; the projection figure is in the specifications above. How much of that reach is useful in your burner depends on tip depth, which is set by the mounting face and the threaded end of the nozzle. That is why we ask for the port depth alongside the thread size rather than the thread alone.

What air supply does the nozzle need?

Compressed air, connected to the rear port through the push-to-connect fitting. The air is both the plasma medium and the purge that keeps the front face clear between starts, so it should be dry and free of oil and grit. Pressure and flow depend on the burner size and the ignition unit driving it, so confirm the figure with us when you order rather than assuming the plant air pressure is suitable.

Can it replace the plasma ignition electrode already in my burner?

Yes, provided the port dimensions match. The plasma ignition electrode is supplied here as a complete nozzle assembly, so the thread, the reach to the tip and the two rear ports are matched to the part you are taking out. A photograph of the old part next to a rule is often enough to start; a drawing or the worn part is better.

How do I confirm it will fit a port drilled to an old or lost drawing?

Send whatever survives: the original drawing, a sketch with the dimensions, or the worn part. We build the nozzle against the port you actually have, including obsolete thread forms and non-standard depths, so the fit is set by measurement rather than by a model name. Thread, depth, tip position and the layout of the two rear ports are the four things to measure.

How is this different from a semiconductor ignition nozzle?

A semiconductor nozzle makes its spark across a glazed ceramic surface at the tip and needs no air line. This nozzle makes a plasma torch and needs compressed air at the rear port, which is what gives it the length to reach a difficult mixture. If your burner port has an air connection and the fuel is hard to light, the plasma nozzle is the matching part; if the port carries a semiconductor electrode with no air supply, the electrode nozzle is the one to fit.

Can you supply a nozzle for a burner that is no longer made?

Yes. That is routine work for a custom plasma ignition components manufacturer: send the worn nozzle, a sketch with the port dimensions, or the original drawing if it survived, and the new part is built to match. Where a drawing exists, that alone is usually enough, and we keep it on file so the next order does not start from a measurement exercise again.

CONTACT US