Product Overview
Built as a plasma ignition gun for boiler startup, this is the ignition end of the start-up sequence. It mounts in the burner port and forms a plasma arc at the front, in the fuel and air stream where light-off actually happens. Power arrives through one of the rear ports, a cooling fan connects to the other, and the arc face sits at the far end of a slim stainless body. During light-off the gun works while the burner establishes flame; once the flame detector proves the fire, the gun drops out of the circuit and the burner runs on its own. That duty shapes everything about the design. The front end sees radiant heat, ash and condensate, and it may be asked to fire several times in a row if the first attempt does not hold — so the insulation and the cooling port matter more here than they would on a part that runs continuously. It takes the place of the pilot burner or ignition lance that used to sit in the same port. Instead of a small gas flame that has to stay alight in a cold, damp furnace, the gun makes its own arc on command and hands the burner over to the flame detection system as soon as flame is proved. Typical partners in the chain are the ignition panel, the high-voltage cable feeding the rear power port, and the detector watching the flame from the other side of the windbox. - An arc instead of a pilot flame. The gun ionises the fuel and air at the burner throat and lights the mixture directly, so light-off no longer hangs on a small gas flame staying alight in a cold furnace. - Ceramic insulation inside the body. The high-voltage path is held in a ceramic sleeve rather than pressed against the metal, which keeps the discharge at the tip and reduces the chance of it tracking back along the shell. - Stainless steel outer shell. Radiant heat, condensate and fly ash are everyday conditions at the burner port; the smooth surface also wipes clean without snagging the ceramic beneath it. - A dedicated cooling port. Fan air runs through the gun and past the insulation, which is what allows several start attempts in a row without the front end cooking itself. - Working length. Enough to carry the arc through the quarl and into the moving fuel and air, rather than firing inside the windbox behind it. - Both connections at the cold end. Power and cooling land behind the mounting face, so leads stay off the hot side and can be pulled quickly during a short outage.
Ceramic Insulation & Body Build
The whole design solves one problem: getting a high-voltage discharge to the front of a hot metal tube without letting it escape into the tube itself. The answer here is a ceramic sleeve carried inside a stainless shell. The stainless takes the radiant heat, the ash and the condensate that collects in a cold furnace; the ceramic carries the electrical insulation and holds up under the same heat. The 150 mm plasma ignition gun is a slim cylinder with the arc face at the front and the mounting point behind it, finished smooth so it wipes down without leaving fibres behind.
Insulation rarely fails because of the ceramic itself. It fails because something conductive gets onto it. Carbon from a rich light-off, oil mist carried in the combustion air, conductive dust, or plain condensation can bridge the surface, and the first sign is usually a thin grey or black trace where the discharge has run along the outside instead of forming at the tip. Left alone, that trace grows until the gun sparks to the shell instead of into the burner.
So the sleeve deserves two minutes at every outage. Look at it in good light, blow it out with dry compressed air, and wipe it with a lint-free cloth. Do not use abrasives, and do not handle the ceramic with greasy gloves — a fingerprint is harmless, a smear of oil is not. A spare gun should be stored dry and capped, and never left open in a damp corner of the workshop.
The cooling port does more for insulation life than most fitters expect. Air passing through the gun pulls heat away from the front end and keeps the ceramic below the point where contamination bakes onto it. Once contamination is baked on, cleaning stops working and the gun has to come out of service.
Installation & Start-Up
- Measure before fitting: check the distance from the mounting face to the point where ignition should occur, and confirm the arc face will sit in the fuel and air stream without touching the quarl or any burner internal.
- Seat the 150 mm plasma ignition gun for boiler startup in the burner port and tighten it on the mounting arrangement, keeping the ceramic centred in the bore so it cannot rub as the burner heats and cools.
- Connect the high-voltage feed to the power port at the rear, and route the lead with a drip loop so condensate runs off the cable instead of into the connector.
- Connect the cooling air line to the second rear port and prove air flow before the first start — an ignition attempt with the cooling line off is the quickest way to shorten the life of the front end.
- Run a trial start at purge conditions and watch the arc through the burner sight port: it should establish at the tip, steady, and without flashing back along the body.
- Let the burner establish flame, confirm the flame detector holds its signal, and check that the gun is switched out of the circuit as the sequence intends.
- Note what the trial showed — arc behaviour, cooling air setting, any marks on the ceramic — so the next outage has a baseline to compare against.
Boiler & Furnace Applications
- Cold start on a package or utility boiler. After a long shutdown the furnace is full of cool, damp air and the first light-off is the hardest of the week. The 150 mm plasma ignition gun for boiler startup makes its own arc on command instead of waiting for a pilot flame to settle.
- Relight after a trip or a fuel cut. When the burner has to come back quickly, the gun fires as soon as the sequence calls for it, and the cooling port lets it take repeated attempts without a cooldown between them.
- Process heaters and furnaces. The same arc lights refinery heaters, heat-treatment furnaces and kilns where a pilot lance used to sit in the port, with the flame detector taking over the monitoring duty once flame is proved.
- Burner builds and retrofits. Because the gun is supplied as a standalone part, it can go into a new burner design or replace a unit in an existing port; as an industrial plasma ignition equipment supplier we check the mounting and reach against the burner drawing first.
- Replacing an ageing plasma gun. When the unit in the port has cracked insulation or a burnt tip, match the new gun on length and port arrangement and keep the existing power feed and cooling line where they are.
Specifications
| Product type | Plasma ignition gun |
| Overall length | 150 mm |
| Outer body | Stainless steel |
| Internal insulation | Ceramic sleeve |
| Front end | Plasma arc outlet |
| Rear connections | Two ports — high-voltage power feed and cooling fan |
| Cooling method | Fan air through the rear cooling port |
| Ignition duty | Boiler and furnace start-up |
| Mounting | Burner igniter port |
Ordering & Delivery
- Gather the port details — the burner drawing or a photo with the mounting-face-to-ignition-point distance, the port size and the burner duty — and send them through the contact form. As an industrial plasma ignition equipment supplier we would rather catch a mismatch at quotation than at installation.
- Confirm how the ignition panel feeds the gun and where the cooling air will come from. Both connections are at the rear, so lead and hose lengths are part of the fit.
- Decide the spare position: whether a second gun, a ceramic sleeve or a tip should travel with the order so an outage does not wait on freight.
- Ask your sales contact for the current lead time, quantity breaks and packing for your destination — these are quoted per order and follow the configuration confirmed above.
- Agree the shipping terms and the documents your receiving department needs, and have packing and marking confirmed before dispatch.
- Book the delivery against the burner it will serve and record the configuration ordered, so a repeat order later matches what is already in the port.
Technical Support & Model Matching
Selection decides how well a part performs in service, so our engineers work through it with you. The team comes out of aviation and military ignition work, bringing 18 years of accumulated expertise to the designs we build. Send your operating conditions, a drawing or a worn sample; we help match the model, check interface details and flag anything that will not fit before you order. Because we manufacture in-house from core components through final testing, modifications stay under our control. Installation, commissioning and troubleshooting support continues after delivery.
FAQ
Does the gun need a pilot flame to light the burner?
No. The plasma arc is the ignition source: the gun ionises the fuel and air at the burner throat and lights the mixture directly. The gun therefore removes the step where a small gas pilot has to be kept alight in a cold furnace before the main burner can be opened up. The flame detector still does its usual job of proving flame once the burner is lit.
What are the two connections at the back for?
One port takes the high-voltage power feed from the ignition panel, the other takes cooling fan air. Keep both connected for every start. The cooling air is what holds the front end and the ceramic insulation at a workable temperature, and a gun run without it will not survive a run of failed light-off attempts.
How do I confirm the 150 mm length suits my burner?
Measure from the mounting face to the point where the arc should form, then check that the arc face lands in the fuel and air stream without touching the quarl or any internal part. Send the burner drawing, or a photo with that distance marked, and we will confirm the gun is the right length before the order is released.
How can I tell whether the ceramic insulation is still sound?
Look at the sleeve in good light at every outage. Cracks, chipped edges and thin grey or black traces are the signs that the discharge has started running along the surface instead of forming at the tip. Clean it with dry compressed air and a lint-free cloth; if a trace will not come off, replace the gun rather than putting it back in the port.
What supply does the gun need from my ignition panel?
The high-voltage feed connects at the rear power port, and the panel that drives it is matched to the burner's ignition sequence rather than to the gun on its own. Tell us the output of the panel already on site, or the one going into a new build, and we will confirm the arrangement before dispatch.